8-14 hsb
2
PLUS Series Color LCD Display
Display Unit
Connection
Scanner Connection (master displays)
Connecttheinter-unitcableplugtotherearscannerconnector.Ifyouareusing
aninter-unit extensioncable,connectthisto the displayunit, and connectthe
suppliedcableto the extensioncable.
Thescannerconnectorpinsareshowninthefollowingdiagram,togetherwith
theconnectionsand core colours.
Figure 8-7: Radar Scanner Connection
The
hsb
2
cableis suppliedwith a blankingplug for thescannerconnector
socket.Thisshould be attachedto the repeaterdisplay. Iftherepeaterdisplay
isinstalledin an exposedpositionsealtheblanking platewithsilicon
compound.
1
2
35
4
7
10
11
86
9
13 12
White
Black
Orange
Black
Black
Green
Yellow
Shield
Red
Red
Violet
Blue
Grey
Video
Video RTN
*Battery --ve
Tx Trigger +
Battery --ve
Data I/O +
Tx Trigger --
Battery +ve
Data I/O --
*Battery +ve
Azimuth +
Azimuth --
1
2
3
4
5
6
7
8
9
10
11
12
13
White
Black
Orange
Yellow
Green
Blue
Violet
Grey
Red
Red
Black
Black
8
7
6
5
4
3
2
1
Video
Video Rtn
Tx Trigger +
Tx Trigger --
Data I/O +
Data I/O --
Azimuth +
Azimuth --
Battery +ve
*Battery +ve
*Battery --ve
Battery --ve
D4290B-2
Front view of
Display Cable Connector
Refer to Pathfinder Scanner Owner's
Handbook for connector detail.
Display Scanner
* Not present on 'light', 11 core cables.
Battery +ve/--ve = 12, 24 or 32v.