Raymarine DS400X Specifiche

Navigare online o scaricare Specifiche per no Raymarine DS400X. Raymarine DS400X Product specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 92
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
DS400X &
DS500X
Digital Fishfinders
Owner’s Handbook
Document number: 81234-2
Date: April 2004
Vedere la pagina 0
1 2 3 4 5 6 ... 91 92

Sommario

Pagina 1 - DS400X &

DS400X & DS500XDigital FishfindersOwner’s HandbookDocument number: 81234-2Date: April 2004

Pagina 2

x DS400 and DS500 Digital FishfindersWorldwide Support ... 68Appendix A: Specificati

Pagina 3 - Warranty

Chapter 1: Overview 1Chapter 1: Overview1.1 IntroductionThis handbook describes the DS400X and DS500X Digital Fishfinders. The DS400/500X feature stat

Pagina 4 - Important Information

2 DS400X and DS500X Digital FishfindersThe DS400/500X employs a very high transmission repetition or “ping” rate which, along with the digital adaptiv

Pagina 5 - Safety Notices

Chapter 1: Overview 3GeneralThe DS400/500X system, illustrated below, is comprised of the digital fishfinder, transducer and associated cables. The DS

Pagina 6

4 DS400X and DS500X Digital Fishfinders

Pagina 7 - Contents

Chapter 2: Installation 5Chapter 2: Installation2.1 IntroductionThis chapter provides installation instructions for your DS400/500X.Note: If you wish

Pagina 8

6 DS400X and DS500X Digital FishfindersThe following accessories are available for your A Series Fishfinder: Transducers are supplied with

Pagina 9

Chapter 2: Installation 7• Cable runs: The unit must be located near a DC power source. The power cable supplied is 5 ft (1.5 m), but a longer cable c

Pagina 10

8 DS400X and DS500X Digital FishfindersCutting the transducer cable will severely reduce sonar performance:• Do not cut the transducer cable or remove

Pagina 11 - Chapter 1: Overview

Chapter 2: Installation 9 Figure 2-2: DS500X Unit Dimensions3.46 in(88 mm)5.88 in(149.4 mm)2.66 in(67.6 mm)3.08 in(78.3 mm)2.99 in(76 mm)2.

Pagina 13 - Transducer

10 DS400X and DS500X Digital Fishfinders2.5 Mounting the FishfinderThe DS400/500X can be mounted on a dash, chart table, bulkhead or deckhead using th

Pagina 14

Chapter 2: Installation 115. Remove the mounting bracket knobs, bracket and mounting frame from the unit. Make sure that the unit fits in the cut-out

Pagina 15 - Chapter 2: Installation

12 DS400X and DS500X Digital Fishfinders2.6 System ConnectionsThe rear of the fishfinder provides the following connection sockets:• Power/NMEA• Trans

Pagina 16 - Mounting Location

Chapter 2: Installation 13 The red wire connects to the feed from the positive (+) battery terminal and the black wire connects to the fee

Pagina 17 - 2.4 Cable Runs

14 DS400X and DS500X Digital FishfindersTransducer ConnectionA 25ft (8m) cable is supplied with the transducer. The transducer cable connector has a n

Pagina 18 -

Chapter 3: Getting Started 15Chapter 3: Getting Started3.1 IntroductionThis chapter provides basic instructions to get you started using the DS400/500

Pagina 19

16 DS400X and DS500X Digital Fishfinders Figure 3-1: Demo/Simulator Mode Setup3.4 LCD DisplayWhen you first switch on the fishfinder, the

Pagina 20 - 2.5 Mounting the Fishfinder

Chapter 3: Getting Started 17 Figure 3-2: Typical Fishfinder Display Screen3.5 Interpreting the Sounder ImageThe DS400/500X uses sound wave

Pagina 21 - Chapter 2: Installation 11

18 DS400X and DS500X Digital FishfindersTarget IndicationsWhen the sounder detects a target echo such as a fish, it displays a representative image on

Pagina 22 - 2.6 System Connections

Chapter 3: Getting Started 193.6 Keypad OperationThe DS400X and DS500X have six control keys. Figure 3-3: Keypad FunctionsENTERPressing thi

Pagina 23 - Chapter 2: Installation 13

DS400X and DS500X Digital Fishfinders iiiPrefaceThis handbook describes the Raymarine DS400X and DS500X Digital Fishfinders.Conventions UsedThroughout

Pagina 24 - Transducer Connection

20 DS400X and DS500X Digital FishfindersMENUPress this key to enter Main Menu setup mode.QUITPress this key to back up one menu level. If already at t

Pagina 25 - Chapter 3: Getting Started

Chapter 3: Getting Started 21If the sounder is in split frequency display mode, the VRM is shown in only one window at a time. Figure 3-4:

Pagina 26 - Fishfinder

22 DS400X and DS500X Digital Fishfinders➤ To change Display Pages:Press the PAGE key.Each key press advances the Page screen. Figure 3-5:

Pagina 27 - Chapter 3: Getting Started 17

Chapter 3: Getting Started 233.9 Menu OperationDS400/500X Fishfinder Page functions can be accessed using the controls that are displayed when you pre

Pagina 28 - Target Indications

24 DS400X and DS500X Digital Fishfinders .Scroll SpeedMENURangeFrequencyA-ScopeGAIN MODEGAINCOLOR GAINTVGSounder Int Rej.Second Echo Rej.P

Pagina 29 - 3.6 Keypad Operation

Chapter 4: Main Menu 25Chapter 4: Main Menu 4.1 IntroductionThis chapter provides basic menu functions for using the DS400/500X Digital Fishfinder. Mo

Pagina 30

26 DS400X and DS500X Digital Fishfinders 3. Press the trackpad > key or ENTER to browse the sub-menus. 4. To edit the highl

Pagina 31 - Chapter 3: Getting Started 21

Chapter 4: Main Menu 27 5. For some numerical settings you will press the ENTER key to select and then use the trackpad to increment or dec

Pagina 32 - ➤ To change Display Pages:

28 DS400X and DS500X Digital Fishfinders7. If enabled in the SOUNDER SET UP... menu, the Key Help function displays tips on which keys to press to mak

Pagina 33 - 3.9 Menu Operation

Chapter 4: Main Menu 294.2 Fishfinder Operation ControlsThe fishfinder operation menu items are outlined in Table 4-1 .Table 4-1: Fishfinder Menu Ite

Pagina 34 - Time Format

iv DS400X and DS500X Digital FishfindersImportant InformationThis handbook contains important information on the installation and operation of your ne

Pagina 35 - Chapter 4: Main Menu

30 DS400X and DS500X Digital FishfindersScroll SpeedThis menu item enables you to start and stop the bottom graph display from moving across the scree

Pagina 36 - GAIN MODE

Chapter 4: Main Menu 31The range mode must be set to MANUAL before the range will change. Press UP, DOWN, or MENU.Pressing on the Trackpad or pressi

Pagina 37

32 DS400X and DS500X Digital FishfindersFrequencyThe DS400/500X uses dual frequency sonar—50 kHz and 200 kHz—and can be used in either auto or manual

Pagina 38 - MAIN MENU

Chapter 4: Main Menu 33A-ScopeUse the A-Scope screen to show raw sonar data directly from the transducer beam. This gives you a “real time” image of f

Pagina 39 - Chapter 4: Main Menu 29

34 DS400X and DS500X Digital FishfindersGAIN MODE...The sounder provides GAIN controls to reduce background noise and determine how different strength

Pagina 40 - Scroll Speed

Chapter 4: Main Menu 35GAINThe gain, or sensitivity, of the display adjusts background noise by varying echo strength for display. The value of the ga

Pagina 41 - Chapter 4: Main Menu 31

36 DS400X and DS500X Digital FishfindersYour choices are:• AUTOMATIC: Displays colors based on current conditions (with as many colors as possible) wh

Pagina 42 - Frequency

Chapter 4: Main Menu 37Second Echo RejectionA so-called “second echo” can caused by the sonar signal returning from the bottom, reflecting off the wat

Pagina 43 - Chapter 4: Main Menu 33

38 DS400X and DS500X Digital Fishfinders• View• Zoom magnification• Zoom Mode ViewThe View sub-menu determines how the zoomed area appears on the scre

Pagina 44

Chapter 4: Main Menu 39Zoom x2, x3, x4 MagnificationThis parameter sets the level of display magnification. The greater the zoom, the smaller the area

Pagina 45 - Color Gain

DS400X and DS500X Digital Fishfinders v• Raymarine specified cables are used. Cutting and rejoining these cables can compromise EMC performance and mu

Pagina 46 - Time Variable Gain (TVG)

40 DS400X and DS500X Digital Fishfinders

Pagina 47 - Max. Ping Rate

Chapter 5: Display Set Up 41Chapter 5: Display Set Up5.1 IntroductionThis chapter will help you to become familiar with the functions of the display’s

Pagina 48

42 DS400X and DS500X Digital Fishfinders Figure 5-1: Accessing Display Set Up Menu ItemsD6630-1MENUENTERORRangeFrequencyAUTOMATICAUTOMATIC

Pagina 49

Chapter 5: Display Set Up 43The Display Set Up menu items are listed in Table 5-1 and then described following that.Table 5-1: DISPLAY SET UP... Men

Pagina 50

44 DS400X and DS500X Digital FishfindersBrightnessUse the trackpad < and > keys to select the brightness value from a low of 10% to a high of 10

Pagina 51 - 5.1 Introduction

Chapter 5: Display Set Up 45 Figure 5-2: FISH & DEPTH Target Depth IDsDepth Digit SizeThis setting controls the size of the digital dep

Pagina 52 - Depth Digit Size

46 DS400X and DS500X Digital Fishfinders Figure 5-3: Transparent MenuPALETTE...The DS400/500X offers you six different display color combi

Pagina 53 - Chapter 5: Display Set Up 43

Chapter 5: Display Set Up 47Background ColorWhen the CLASSIC palette is selected, you can also choose the background color used. Three colors are avai

Pagina 54 - Target Depth ID

48 DS400X and DS500X Digital FishfindersNote: When analog gauges are selected, the Navigation Items cannot be dis-played on the Fishfinder page. You

Pagina 55 - Transparent Menu

Chapter 5: Display Set Up 49• RNG/BRG Range and bearing of waypointDisplay ON or OFF• COGCourse Over GroundDisplay ON or OFF• TTGTime to Go before rea

Pagina 56 - DISPLAY SET UP

vi DS400X and DS500X Digital FishfindersRaymarine Products and ServicesRaymarine products are supported by a network of Authorized Service Representat

Pagina 57 - DATA ITEMS

50 DS400X and DS500X Digital Fishfinders Figure 5-5: Displaying Navigation Data40206060D6903-1

Pagina 58

Chapter 6: Sounder Set Up 51Chapter 6: Sounder Set Up6.1 IntroductionOnce you have installed your DS400X or DS500X and are familiar with its basic ope

Pagina 59

52 DS400X and DS500X Digital Fishfinders Figure 6-1: Accessing Sounder Set Up Menu ItemsMENUENTERORRangeFrequencyAUTOMATICAUTOMATICScroll

Pagina 60

Chapter 6: Sounder Set Up 53The following table lists the setup menus and their options and shows the factory default setting. Each parameter is descr

Pagina 61

54 DS400X and DS500X Digital FishfindersSpeed Units KNOTS,MILES PER HOUR,KM PER HOURKNOTSDistance Units NAUTICAL MILES,STATUTE MILES,KILO METERS1,KILO

Pagina 62 - 0.00 ft

Chapter 6: Sounder Set Up 551METERS settings only available in CE modelsALARMS...This menu group is used to set up alarms that are available to alert

Pagina 63 - Chapter 6: Sounder Set Up 53

56 DS400X and DS500X Digital Fishfinders Figure 6-2: FISH & DEPTH Target Depth IDsFish AlarmIf this alarm is ON, the unit sounds a bee

Pagina 64

Chapter 6: Sounder Set Up 57Deep AlarmIf this alarm is ON and the depth below the boat is greater than the value set using the Deep Range setting, the

Pagina 65 - ALARMS

58 DS400X and DS500X Digital Fishfinders Figure 6-4: Temperature Alarm with Standard & Analog GaugesTemp. Rng. HighUse the < and &g

Pagina 66 - Shallow Range

Chapter 6: Sounder Set Up 596. When the alarm clock sounds, it is accompanied by a message box labeled ALARM CLOCK displaying the time.The default set

Pagina 67 - Temp. Alarm

viiContentsPreface ... iiiConvention

Pagina 68 - ALARM CLOCK

60 DS400X and DS500X Digital FishfindersBearing Mode• TRUE (default)• MAGNETIC Date Format• MM/DD/YY (default)• DD/MM/YY Time Format• 12 HOUR (default

Pagina 69 - UNITS

Chapter 6: Sounder Set Up 61LanguageSelect the language in which you wish information to be displayed. The selected language will be used for all scre

Pagina 70 - NMEA-OUT SET UP

62 DS400X and DS500X Digital FishfindersDepth OffsetThe depth offset is added to the measured depth value before it is displayed. You can specify the

Pagina 71 - Key Help

Chapter 7: Maintenance and Problem Solving 63Chapter 7: Maintenance and Problem SolvingThis chapter provides information on routine maintenance and on

Pagina 72 - Sounder Simulator

64 DS400X and DS500X Digital FishfindersUse only a water-based antifouling paint, or a water-based paint specifically designed for transducers. Apply

Pagina 73 - 7.1 Maintenance

Chapter 7: Maintenance and Problem Solving 657.2 Problem SolvingAll Raymarine products are, prior to packing and shipping, subjected to comprehensive

Pagina 74 - Cleaning the Hull

66 DS400X and DS500X Digital Fishfinders7.3 How to Contact RaymarineOn the InternetVisit the Raymarine World Wide Web site for the latest information

Pagina 75 - 7.2 Problem Solving

Chapter 7: Maintenance and Problem Solving 67However, if you are in need of an item not available from the retailer, please contact Raymarine Technica

Pagina 76 - 7.3 How to Contact Raymarine

68 DS400X and DS500X Digital FishfindersThe Product Repair Center is open Monday through Friday 8:15 a.m. to 5:00 p.m. Eastern Time. All products retu

Pagina 77 - Product Repair and Service

Appendix A: Specifications 69 Appendix A: SpecificationsGeneralCE Conforms to 89/336/EEC (EMC)Size DS400XDS500XH x W x D, excluding mounting bracket4

Pagina 78 - Worldwide Support

viii DS400 and DS500 Digital FishfindersChapter 4: Main Menu ...2

Pagina 79 - Appendix A: Specifications

70 DS400X and DS500X FishfindersNMEA DataConnector Received TransmittedPOWER/NMEA BWC, BWR, GLL, ZDA, RMB, VTG, HDG, HDTBWC, BWR, DBT, DPT, GLL, MTW,

Pagina 80 - NMEA Data

71IndexAAccessories 6Obtaining 66Alarm Clock 49, 58Alarms 55Alarm Clock 58Deep Alarm 57Deep Range 57Fish Alarm 56Shallow Alarm 56Shallow Range 56Tar

Pagina 81

72 DS400 and DS500 Digital FishfindersEEchoes 16Strength 17ENTER key 19FFeatures 2Fish Alarm 56FishfinderBasic System 2Typical Display Screen 17Fishfi

Pagina 82

73Date 49Date Format 49LAT/LONG 48RNG/BRG 49SOG 48Time 49Time Format 49Time Offset 49TTG 49Waypoint 48Navigation Data 48NMEA-out Set Up 60PPage 20,

Pagina 83

74 DS400 and DS500 Digital FishfindersSpeed 47Speed Calibrate 62Speed Units 59Supplied Parts 5SystemConnections 12TTarget Depth ID 44, 55Target Indica

Pagina 84

DS400X Flush Mount Template TOP90 mmCut out with3-5/8" hole sawRemoveshaded areasonly2.99" (76 mm)2.83" (72 mm)D6649-2

Pagina 85 - 2.83" (72 mm)

DS400 Mounting Template

Pagina 86 - DS400 Mounting Template

DS500X Flush Mount TemplateTOP90mmCut out with3-5/8"hole sawRemoveshaded areasonly2.83"(72mm)2.99" (76 mm)D6650-2

Pagina 88 - DS500 Mounting Template

Warranty CertificateIn order to ensure that the equipment continues to operate efficiently and reliably, we recom-mend that before using the product,

Pagina 89 - Warranty Limitations

ixDeep Range ... 57Temp. Alarm ...

Pagina 90 - September 2003

Document number: 84161-1September 2003Consumable items, including, but not limited to: fuses, batteries, drive belts, radar mixer diodes, snap-in impe

Pagina 91 - Factory Service Centers

Factory Service CentersUnited States of America UK, Europe, Middle East, Far EastRaymarine Inc22 Cotton Road, Unit DNashua, NH 03063-4219

Pagina 92

Warranty

Commenti su questo manuale

Nessun commento